Find the smallest wire gauge that meets ampacity and voltage drop limits for a circuit's current, length, voltage and material.

  • Runs in your browser
  • Nothing uploaded

The tool

Enter your numbers below. Results update as you type, and nothing leaves your browser.

Everything you enter stays on your own machine. Nothing is sent to us or to anyone else, which you can confirm in your browser network tab.

What people use it for

  • Sizing a sub-panel feeder
  • Running power to an outbuilding
  • Checking voltage drop on long runs
  • EV charger circuit planning

About this tool

What the Wire Size Calculator does

Wire must carry the current without overheating (ampacity) and without losing too much voltage over its length. Long runs often need a larger wire than ampacity alone suggests. This calculator checks both: ampacity from the common 75°C insulation column and voltage drop from conductor resistance.

It also works as a wire gauge ampacity calculator or a voltage drop calculator.

Formula

  • Voltage drop (single phase) = 2 × K × I × L ÷ circular mils
  • Three phase uses √3 instead of 2
  • K ≈ 12.9 for copper and 21.2 for aluminium
  • Ampacity from the 75°C column of standard conductor tables

Worked example

Using the starting values in the calculator above:

Input Value
Load current 40 A
One-way circuit length 75 ft
Voltage 240
Phase Single phase
Conductor Copper
Maximum voltage drop 3%
Result Value
Recommended wire size 8 AWG
Size set by Ampacity
Voltage drop at that size 1.95%
Voltage drop 4.69
Smallest size by ampacity alone 8 AWG

How to read the result

Breaker size, terminal temperature ratings, conduit fill, ambient temperature and continuous-load rules can all require a larger wire than this result.

Small conductors have their own overcurrent limits in the NEC (for example 14 AWG copper on 15 A, 12 AWG on 20 A).

For planning only. Electrical, gas and refrigerant work must follow current codes and be carried out or checked by a licensed professional.

Related calculators

Browse every calculator in Electrical, HVAC and Plumbing Calculators, or talk to us about websites and booking systems for trade businesses.

Questions

Questions about this tool

The things clients actually want to know — costs, timelines, ownership and what happens after launch.

Copper 8 AWG is commonly used at 40 A on short runs with 75°C terminations, but long runs may need 6 AWG to limit voltage drop.

A common recommendation is 3% for a branch circuit and 5% total including the feeder.

It has higher resistance and lower ampacity than copper of the same gauge.

Free strategy session

Let’s build something worth finding.

Tell us where you want the business to be in twelve months. We will come back with a costed plan, a realistic timeline, and the numbers we expect to move — no obligation, no jargon.

  • 30-minute call, no pitch deck
  • Fixed-price proposal in 48 hours
  • You own everything we build

Talk to a developer

Not a sales team

Response time
Within 1 business hour
Where we work
UK, USA & the Gulf
Contracts
No lock-in, monthly rolling
Working since
2023
infobestwebdeveloper.org

Free strategy session

Let’s build something worth finding.

Tell us where you want the business to be in twelve months. We will come back with a costed plan, a realistic timeline, and the numbers we expect to move — no obligation, no jargon.

  • 30-minute call, no pitch deck
  • Fixed-price proposal in 48 hours
  • You own everything we build

Talk to a developer

Not a sales team

Response time
Within 1 business hour
Where we work
UK, USA & the Gulf
Contracts
No lock-in, monthly rolling
Working since
2023
infobestwebdeveloper.org
Free consultation